杨文强.液化地基土抗液化措施的分析计算[J].矿产勘查,2018,9(3):522-526 |
液化地基土抗液化措施的分析计算 |
Analysis and calculation of anti-liquefaction treatment for the liquefaction foundation |
投稿时间:2018-02-06 |
DOI: |
中文关键词: 液化指数 液化等级 消除液化 挤密碎石桩 |
英文关键词: liquefaction index, liquefaction lever, eliminate liquefaction, sand-gravel Columns |
基金项目: |
|
摘要点击次数: 2349 |
全文下载次数: 2099 |
中文摘要: |
建筑场地抗震设防烈度为7度及以上时,地基土为饱和砂土和饱和粉土,应进行液化判别,存在液化土层的地基,应根据建筑的抗震设防类别、地基的液化等级,结合具体情况采取相应的措施。地基的液化等级为中等、建筑抗震设防类别为丙类时,可采取挤密碎石桩部分消除地基液化沉陷。当经挤密碎石桩处理后地基土为轻微液化时,按照规范,对于抗震设防类别为丙类时,可不用采取抗液化措施。抗液化措施采取部分消除地基液化,解决了地基土的液化问题,对工程也相对比较经济和合理。 |
英文摘要: |
Liquefaction discrimination should be done if the seismic precautionary intensity of the building site is 7 degrees and above and the foundation are saturated soil & saturated sand. If the foundation has liquefaction soil, we can take corresponding measures according to the seismic precautionary intensity or liquefaction lever . In the case of liquefaction lever is medium and seismic precautionary intensity is C class, sand-gravel columns can be used to eliminate liquefaction settlement. If foundation soils are slight liquefaction after sand-gravel columns, anti-liquefaction measures needn’t to be taken in case of seismic precautionary intensity is C class according to the codes. Liquefaction of foundation soil is settled by the anti-liquefaction measures of partial elimination of foundation liquefaction .It is Economic and reasonable for the construction engineering. |